Battery generator

Power without a combustion engine: no exhaust, no refuelling, no idling noise. Portable at 230 V, and 400 V three-phase when run as a bank — for demolition, installation, dewatering and night work.

Three questions before you buy

  1. How much load runs at the same time? Add up the input ratings of the tools that run in parallel — not every tool in the yard.
  2. How long must it run without recharging? Runtime is usable capacity divided by actual load. Doing that division once shows whether one unit is enough or the combustion unit has to stay.
  3. Does any equipment need 400 V three-phase? Then the answer is a bank of three units, not a larger single-phase box.

Limits worth knowing beforehand

  • Standalone operation for days: without grid or recharge, a combustion generator still wins. A battery covers shifts, not weeks.
  • Load held at the ceiling: headroom is there for starting currents, not for hours at the limit.
  • Three units plus cabling weigh more than a can of diesel — transport, cabling and theft protection belong in the plan.

P-series parallel power systems

One modular platform. Add parallel units where the load grows — two or three units single-phase, or three units for 400 V three-phase.

ConfigurationUnitsRated powerUsable capacityWeightOutput
P2512,500 W2.7 kWh29 kg230 V / 16 A · single-phase
P25 + P25-D25,000 W5.4 kWh≈60 kg230 V · single-phase · AC230V/20A output
P25 + P25-D37,500 W8.1 kWh≈90 kg230 V · single-phase · AC230V/30A output
P25 + P25-T37,500 W8.1 kWh≈90 kg400 V · three-phase · AC400V/10A output
  • P25

    Units
    1
    Rated power
    2,500 W
    Usable capacity
    2.7 kWh
    Weight
    29 kg
    Output
    230 V / 16 A · single-phase
  • P25 + P25-D

    Units
    2
    Rated power
    5,000 W
    Usable capacity
    5.4 kWh
    Weight
    ≈60 kg
    Output
    230 V · single-phase · AC230V/20A output
  • P25 + P25-D

    Units
    3
    Rated power
    7,500 W
    Usable capacity
    8.1 kWh
    Weight
    ≈90 kg
    Output
    230 V · single-phase · AC230V/30A output
  • P25 + P25-T

    Units
    3
    Rated power
    7,500 W
    Usable capacity
    8.1 kWh
    Weight
    ≈90 kg
    Output
    400 V · three-phase · AC400V/10A output

Wiring

The parallel distribution unit carries one power input and one data input per battery unit, and a single output to the load.

  • P25-D2 × P25P25 1P25 2AC230V/20A
    AC230V/20ATwo P25 units, 230 V single-phase.
  • P25-D3 × P25P25 1P25 2P25 3AC230V/30A
    AC230V/30AThree P25 units, 230 V single-phase.
  • P25-T3 × P25P25 1P25 2P25 3AC400V/10A
    AC400V/10AThree 230 V P25 units in parallel make 400 V three-phase — all three required, or the system loses a phase.

How the parallel link is wired

  1. Each P25 runs one power cable and one data cable to its own input pair on the distribution unit.
  2. The distribution unit has three input pairs (L1 / L2 / L3); one pair per battery unit.
  3. Only the distribution unit output feeds the load. Battery units are never connected to the load directly.
  4. Each unit keeps its own protective device; no unit back-feeds another.

Three configurations, one platform

Start with a single unit and add parallel units only when the load demands it. Every configuration runs the same battery unit and the same distribution unit.

  • Hitama P25 portable industrial battery power station, three-quarter view on white

    P25

    The core unit. A fanless, self-cooling 230 V power station that replaces the combustion generator on site — no exhaust, no idling noise, no fuel run.

    Key figures

    Rated power
    2,500 W
    Peak power
    5,000 W (≤10 s)
    Usable capacity
    2.7 kWh
    Output
    230 V · 16 A
    Protection
    IP54
    Weight
    29 kg
    Request a quote
  • Hitama P25-D parallel distribution unit for two P25 power stations

    P25 + P25-D

    Two or three units linked through the parallel distribution unit for 230 V single-phase loads. Power and capacity stack — start with two, add a third when the job needs it.

    Key figures

    Units
    2–3 × P25
    Rated power
    5,000–7,500 W
    Usable capacity
    5.4–8.1 kWh
    Output
    AC230V · 20–30 A
    Request a quote
  • Hitama P25-T three-phase parallel distribution unit for three P25 power stations

    P25 + P25-T

    Three 230 V P25 units in parallel produce the 400 V three-phase supply that runs tools which will not start on single phase. All three are required — remove one and the system loses a phase. Carried and assembled by hand: no crane, no lifting gear.

    Key figures

    Units
    3 × 230V P25
    Rated power
    7,500 W
    Usable capacity
    8.1 kWh
    Output
    AC400V · 10 A three-phase
    Request a quote

Feature overview

Every part, numbered on the real machine — the same order as the wiring diagrams above.

P25 — the workhorse unit

Hitama P25 site power station front port panel: AC output socket, AC charging input, power switch, battery display, USB-C, solar input, parallel power and data ports12345678
Port panel
  1. AC output · 230 V / 16 APlug cutters, welders and drills straight in.
  2. AC charging inputOn grid power, charge it overnight.
  3. Power switchOne turn starts the station.
  4. Battery displaySix LEDs — charge readable from the doorway.
  5. USB-CKeeps phones and laptops topped up.
  6. Solar inputFit a panel, keep charging on site.
  7. Parallel power portPower line to the P25-D / P25-T box.
  8. Parallel data portData line — the units stay in sync.
Hitama P25 portable power station three-quarter view: carry handle, IP54 enclosure, 2.7 kWh battery body123
Body
  1. Carry handle29 kg — carried by hand to the load.
  2. IP54 enclosureDust-protected, spray-water protected.
  3. 2.7 kWh batteryUsable capacity per unit, fanless.

P25-D — 230 V parallel box

Hitama P25-D parallel distribution box front view: mounting hook, AC230V-30A output, breaker protection window, six parallel input ports1234567891011
Front
  1. Mounting hookHang the P25 units on the box.
  2. EnclosureThe parallel box — ready out of the crate.
  3. Parallel output · AC230V-30AThe only feed to the load.
  4. Mounting stopHolds the box in place on the ground.
  5. Protection device areaThe breakers, behind a protected window.
  6. Parallel 1 inputP25 No.1 power line — AC230V-10A.
  7. Parallel 1 data inputP25 No.1 data line.
  8. Parallel 2 inputP25 No.2 power line — AC230V-10A.
  9. Parallel 2 data inputP25 No.2 data line.
  10. Parallel 3 inputP25 No.3 power line — AC230V-10A.
  11. Parallel 3 data inputP25 No.3 data line.

P25-T — 400 V three-phase box

Hitama P25-T three-phase parallel box front view: mounting hook, AC400V-10A output, breaker protection window, six parallel input ports1234567891011
Front
  1. Mounting hookHang the P25 units on the box.
  2. EnclosureThe three-phase box — ready out of the crate.
  3. Parallel output · AC400V-10AThree-phase — the only feed to the load.
  4. Mounting stopHolds the box in place on the ground.
  5. Protection device areaThe breakers, behind a protected window.
  6. Parallel 1 input · L1P25 No.1 power line — AC230V-10A.
  7. Parallel 1 data inputP25 No.1 data line.
  8. Parallel 2 input · L2P25 No.2 power line — AC230V-10A.
  9. Parallel 2 data inputP25 No.2 data line.
  10. Parallel 3 input · L3P25 No.3 power line — AC230V-10A.
  11. Parallel 3 data inputP25 No.3 data line.

Optional accessory

Put the sun to work. A 400 W folding panel clips into the P25 solar input — charge on site, no mains. Parallel two of them: 800 W into the station.

Hitama 400 W folding solar panel for the P25 — unfolded four-section panel, folded case with orange handle, and a 3 m MC4 cable

Optional

Folding Solar Panel 400 W

One panel, 400 W. Folds flat, carries by hand, plugs into the P25 solar input. Parallel two panels — 800 W charging the station together.

Max. power (Pmax)
400 W
Voltage at Pmax (Vmp)
72 V
Current at Pmax (Imp)
5.56 A
Open-circuit voltage (Voc)
86.4 V
Short-circuit current (Isc)
5.89 A
Max. system voltage
1000 V
Connector
MC4
Frame
ETFE
Protection
IP54
Weight
9.1 kg
Size, folded
612 × 590 × 50 mm
Size, unfolded
2230 × 590 × 25 mm
Operating temperature
-40 °C to +70 °C
In the box
3 m connection cable
Request a quote

For dealers and rental fleets

  • OEM and ODM: we work with partners on such projects — from custom logo printing to an adapted configuration.
  • Custom logo printing is available.
  • Tell us configuration, voltage and volume; we confirm feasibility, any tooling required, and the lead time.

Where it replaces the combustion generator

  • Indoors, in tunnels and in shafts where exhaust cannot stay.
  • Night work and residential areas: no engine noise, no idling for hours.
  • No refuelling, no oil changes, no cold start in frost — it stands for months and is still ready to run.
  • Fanless cooling with no intake opening, so dust and chips have nothing to clog.

Datasheet and dealer terms

Technical data, conformity and transport conditions are in the datasheet. To size a system we need three things: the tools and their input ratings, the runtime you need, and whether 400 V is required.

Frequently asked questions

The questions buyers actually ask before a first order — answered with numbers from our own datasheets, not from a brochure.

Is a battery generator a generator?

In outcome yes, in construction no. Nothing drives a generator; storage is discharged through an inverter. Hence no fuel, no engine, no exhaust — and no maintenance on oil, spark plug or exhaust.

What does a battery generator cost to run?

Electricity instead of diesel, plus the charging effort. What matters are the utilisation days: no refuelling, no oil change, no cold start. For rental, turnaround counts, not the price per litre.

Which power class suits which model?

It depends on continuous load, voltage and runtime, not on a single figure. Tell us the loads and the duration; the mapping to P-series or C24 follows from that.

Does the unit charge more slowly in cold weather?

Charging at frost is limited; discharge still works. For winter operation that is the relevant difference to a generator: it does not start worse, it only charges more slowly.