Power without a combustion engine: no exhaust, no refuelling, no idling noise. Portable at 230 V, and 400 V three-phase when run as a bank — for demolition, installation, dewatering and night work.
Three questions before you buy
How much load runs at the same time? Add up the input ratings of the tools that run in parallel — not every tool in the yard.
How long must it run without recharging? Runtime is usable capacity divided by actual load. Doing that division once shows whether one unit is enough or the combustion unit has to stay.
Does any equipment need 400 V three-phase? Then the answer is a bank of three units, not a larger single-phase box.
Limits worth knowing beforehand
Standalone operation for days: without grid or recharge, a combustion generator still wins. A battery covers shifts, not weeks.
Load held at the ceiling: headroom is there for starting currents, not for hours at the limit.
Three units plus cabling weigh more than a can of diesel — transport, cabling and theft protection belong in the plan.
P-series parallel power systems
One modular platform. Add parallel units where the load grows — two or three units single-phase, or three units for 400 V three-phase.
Configuration
Units
Rated power
Usable capacity
Weight
Output
P25
1
2,500 W
2.7 kWh
29 kg
230 V / 16 A · single-phase
P25 + P25-D
2
5,000 W
5.4 kWh
≈60 kg
230 V · single-phase · AC230V/20A output
P25 + P25-D
3
7,500 W
8.1 kWh
≈90 kg
230 V · single-phase · AC230V/30A output
P25 + P25-T
3
7,500 W
8.1 kWh
≈90 kg
400 V · three-phase · AC400V/10A output
P25
Units
1
Rated power
2,500 W
Usable capacity
2.7 kWh
Weight
29 kg
Output
230 V / 16 A · single-phase
P25 + P25-D
Units
2
Rated power
5,000 W
Usable capacity
5.4 kWh
Weight
≈60 kg
Output
230 V · single-phase · AC230V/20A output
P25 + P25-D
Units
3
Rated power
7,500 W
Usable capacity
8.1 kWh
Weight
≈90 kg
Output
230 V · single-phase · AC230V/30A output
P25 + P25-T
Units
3
Rated power
7,500 W
Usable capacity
8.1 kWh
Weight
≈90 kg
Output
400 V · three-phase · AC400V/10A output
Wiring
The parallel distribution unit carries one power input and one data input per battery unit, and a single output to the load.
AC230V/20ATwo P25 units, 230 V single-phase.
AC230V/30AThree P25 units, 230 V single-phase.
AC400V/10AThree 230 V P25 units in parallel make 400 V three-phase — all three required, or the system loses a phase.
How the parallel link is wired
Each P25 runs one power cable and one data cable to its own input pair on the distribution unit.
The distribution unit has three input pairs (L1 / L2 / L3); one pair per battery unit.
Only the distribution unit output feeds the load. Battery units are never connected to the load directly.
Each unit keeps its own protective device; no unit back-feeds another.
Three configurations, one platform
Start with a single unit and add parallel units only when the load demands it. Every configuration runs the same battery unit and the same distribution unit.
P25
The core unit. A fanless, self-cooling 230 V power station that replaces the combustion generator on site — no exhaust, no idling noise, no fuel run.
Two or three units linked through the parallel distribution unit for 230 V single-phase loads. Power and capacity stack — start with two, add a third when the job needs it.
Three 230 V P25 units in parallel produce the 400 V three-phase supply that runs tools which will not start on single phase. All three are required — remove one and the system loses a phase. Carried and assembled by hand: no crane, no lifting gear.
Technical data, conformity and transport conditions are in the datasheet. To size a system we need three things: the tools and their input ratings, the runtime you need, and whether 400 V is required.
The questions buyers actually ask before a first order — answered with numbers from our own datasheets, not from a brochure.
Is a battery generator a generator?
In outcome yes, in construction no. Nothing drives a generator; storage is discharged through an inverter. Hence no fuel, no engine, no exhaust — and no maintenance on oil, spark plug or exhaust.
What does a battery generator cost to run?
Electricity instead of diesel, plus the charging effort. What matters are the utilisation days: no refuelling, no oil change, no cold start. For rental, turnaround counts, not the price per litre.
Which power class suits which model?
It depends on continuous load, voltage and runtime, not on a single figure. Tell us the loads and the duration; the mapping to P-series or C24 follows from that.
Does the unit charge more slowly in cold weather?
Charging at frost is limited; discharge still works. For winter operation that is the relevant difference to a generator: it does not start worse, it only charges more slowly.