A rental fleet does not lose money because a machine is old. It loses money because a quarter of it stands still while the invoice says booked.

Booking days measure demand, not use

A unit can go out twenty days a month and deliver a fraction of the energy it could have sold. Rental systems count days because days get invoiced. A booking proves the unit left the yard and came back; it says nothing about how much of the 2.7 kWh it carries reached a tool. Two units on identical calendars can differ fourfold in delivered energy, and the lower one is sold first at season's end.

The arithmetic of a full shift explains the gap. 2.7 kWh against 2,500 W continuous is about one hour at rated output. A ten-hour shift at that load would be 25 kWh, roughly nine units sharing the work. Almost no rental load looks like that, which is why a booking calendar cannot stand in for use.

The denominator has to be the fleet-day. Every unit, every day it stood available, including the days it stood still. With both numbers side by side the idle quarter stops being an opinion: it is the one below the other three for two consecutive months.

Three numbers, and only three

Delivered kWh per available unit-day comes first. It survives a change of customer, trade or season, because it divides what left the battery by what could have. A unit delivering 1.1 kWh on twenty days moves 22 kWh a month; at one hour of rated output a day it would move 54.

Second is how much of the peak headroom was used. The P25 gives 5,000 W for at most ten seconds and 2,500 W continuously. If recorded start transients never approach that ceiling, the second unit bought for the parallel configuration is capacity you store instead of rent.

Third is the hours between return and rentable. A full charge takes about two and a half hours, 80% about two, at 500 to 1,500 W of charging input. At the top of that window the pack is ready in two and a half hours; at 500 W the same 2.7 kWh needs about five and a half. One unit makes a seven o'clock departure, the other only the afternoon — same return time, different socket.

What the meter cannot tell you

Discharged energy says how much, not how hard. 2.7 kWh over nine hours is a different rental from 2.7 kWh in forty minutes, and only the second one keeps a welder working through a shift.

Charging energy is the easiest number to measure and the least useful. It includes depot standby, balancing and the hour the unit sat on the charger because nobody unplugged it. Reported as utilisation, it flatters the fleet every month.

What to stop looking at

State of charge at a fixed hour is a picture of the charging schedule, not of demand. A unit at 40% at six in the evening may have run flat by noon, or never have been switched on. On a five-minute poll both look identical.

Position tells you where the unit is, not whether it worked. A machine parked for a week with nothing plugged in draws the same trail as one that ran every day.

What this is not

This is not an argument for more telemetry. Three numbers and one denominator, every month. A depot writing delivered kWh and return time on a sheet finds the idle quarter faster than one reading forty dashboard fields.

This is not a claim that idle time is waste. A spare unit, a seasonal peak, a customer who wants a standby machine: all of that is idle by design.

This is not a statement about what our units record. The P25 is a power station: 2,500 W continuous, 5,000 W for ten seconds, 2.7 kWh, 29 kg, 230 V at 16 A, fanless, IP54 as a housing rating. What a unit logs, where that data goes and who may see it is a procurement question to settle in writing before the first delivery.

The paragraph that belongs in the contract

Site location and load curve describe a customer's production, not your machine. An agreement that streams load curves into a shared dashboard without saying so is a data-protection problem with a service label. Write down what is uploaded, how long it is kept, and whether the site coordinates appear in a view the customer's own client can open.

Then make the export a condition of the deal. If delivered kWh per unit-day cannot come out as a sortable column, the reporting is decoration. Send us the tools, the shift pattern and the return times you actually run, and we size the units and the charging window against them: https://www.hitama.net/en/contact